92 research outputs found

    Coronary calcification and risk of cardiovascular disease

    Get PDF

    Coronary calcification and risk of cardiovascular disease

    Get PDF

    Lung cancer screening

    Get PDF
    Randomised controlled trials, including the National Lung Screening Trial (NLST) and the NELSON trial, have shown reduced mortality with lung cancer screening with low-dose CT compared with chest radiography or no screening. Although research has provided clarity on key issues of lung cancer screening, uncertainty remains about aspects that might be critical to optimise clinical effectiveness and cost-effectiveness. This Review brings together current evidence on lung cancer screening, including an overview of clinical trials, considerations regarding the identification of individuals who benefit from lung cancer screening, management of screen-detected findings, smoking cessation interventions, cost-effectiveness, the role of artificial intelligence and biomarkers, and current challenges, solutions, and opportunities surrounding the implementation of lung cancer screening programmes from an international perspective. Further research into risk models for patient selection, personalised screening intervals, novel biomarkers, integrated cardiovascular disease and chronic obstructive pulmonary disease assessments, smoking cessation interventions, and artificial intelligence for lung nodule detection and risk stratification are key opportunities to increase the efficiency of lung cancer screening and ensure equity of access.</p

    Alcohol consumption and risk of peripheral arterial disease: the Rotterdam study

    Get PDF
    Moderate alcohol consumption is associated with a reduced risk of cardiovascular disease. Data on alcohol consumption and atherosclerosis are scarce. To determine the association between alcohol consumption and risk of peripheral arterial disease, the authors carried out a cross-sectional study (1990-1993) in the population-based Rotterdam Study among men and women aged 55 years or over. Data on alcohol consumption and peripheral arterial disease, as measured by the ankle/brachial blood pressure index, were available for 3,975 participants without symptomatic cardiovascular disease. Male

    Accurate late gadolinium enhancement prediction by early T1-based quantitative synthetic mapping

    Get PDF
    OBJECTIVES: Early synthetic gadolinium enhancement (ESGE) imaging from post-contrast T1 mapping after adenosine stress-perfusion cardiac magnetic resonance (CMR) was compared to conventional late gadolinium enhancement (LGE) imaging for assessing myocardial scar. METHODS: Two hundred fourteen consecutive patients suspected of myocardial ischaemia were referred for stress-perfusion CMR. Myocardial infarct volume was quantified on a per-subsegment basis in both synthetic (2-3 min post-gadolinium) and conventional (9 min post-gadolinium) images by two independent observers. Sensitivity, specificity, PPV and NPV were calculated on a per-patient and per-subsegment basis. RESULTS: Both techniques detected 39 gadolinium enhancement areas in 23 patients. The median amount of scar was 2.0 (1.0-3.1) g in ESGE imaging and 2.2 (1.1-3.1) g in LGE imaging (p=0.39). Excellent correlation (r=0.997) and agreement (mean absolute difference: -0.028±0.289 ml) were found between ESGE and LGE images. Sensitivity, specificity, PPV and NPV of ESGE imaging were 96 (78.9-99.9), 99 (97.1-100.0)%, 96 (76.5-99.4) and 99.5 (96.6-99.9) in patient-based and 99 (94.5-100.0), 100 (99.9-100.0)%, 97.0 (91.3-99.0) and 100.0 (99.8-100.0) in subsegment-based analysis. CONCLUSION: ESGE based on post-contrast T1 mapping after adenosine stress-perfusion CMR imaging shows excellent agreement with conventional LGE imaging for assessing myocardial scar, and can substantially shorten clinical acquisition time. KEY POINTS: • Synthetic gadolinium enhancement images can be used for detection of myocardial scar. • Early synthetic gadolinium enhancement images can substantially shorten clinical acquisition time. • ESGE has high diagnostic accuracy as compared to conventional late gadolinium enhancement. • Quantification of myocardial scar with ESGE closely correlates with conventional LGE. • ESGE after stress perfusion CMR avoids need for additional gadolinium administration

    PHP48 COST SENSITIVENESS AND PHYSICIAN TREATMENT CHOICES

    Get PDF
    Objectives To explore the relationship between nodule count and lung cancer probability in baseline low-dose CT lung cancer screening. Materials and Methods Included were participants from the NELSON trial with at least one baseline nodule (3392 participants [45% of screen-group], 7258 nodules). We determined nodule count per participant. Malignancy was confirmed by histology. Nodules not diagnosed as screen-detected or interval cancer until the end of the fourth screening round were regarded as benign. We compared lung cancer probability per nodule count category. Results 1746 (51.5%) participants had one nodule, 800 (23.6%) had two nodules, 354 (10.4%) had three nodules, 191 (5.6%) had four nodules, and 301 (8.9%) had > 4 nodules. Lung cancer in a baseline nodule was diagnosed in 134 participants (139 cancers; 4.0%). Median nodule count in participants with only benign nodules was 1 (Inter-quartile range [IQR]: 1–2), and 2 (IQR 1–3) in participants with lung cancer (p = NS). At baseline, malignancy was detected mostly in the largest nodule (64/66 cancers). Lung cancer probability was 62/1746 (3.6%) in case a participant had one nodule, 33/800 (4.1%) for two nodules, 17/354 (4.8%) for three nodules, 12/191 (6.3%) for four nodules and 10/301 (3.3%) for > 4 nodules (p = NS). Conclusion In baseline lung cancer CT screening, half of participants with lung nodules have more than one nodule. Lung cancer probability does not significantly change with the number of nodules. Baseline nodule count will not help to differentiate between benign and malignant nodules. Each nodule found in lung cancer screening should be assessed separately independent of the presence of other nodules

    Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    Get PDF
    To assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced low-radiation-dose chest CT for lung cancer screening were included. Non-imaging predictors (age, smoking status and pack-years) were collected and imaging-predictors (calcium volume of the coronary arteries, aorta, aortic valve and mitral valve/annulus) were obtained. The outcome was the occurrence of cardiovascular events. Multivariable Cox proportional-hazards regression was used to calculate hazard-ratios (HRs) with 95 % confidence interval (CI). Subsequently, concordance-statistics were calculated. In total 3111 individuals were included, of whom 186 (6.0 %) developed a cardiovascular event during a follow-up of 2.9 (Q1–Q3, 2.7–3.3) years. If aortic (n = 657) or mitral (n = 85) annulus/valve calcifications were present, cardiovascular event incidence increased to 9.0 % (n = 59) or 12.9 % (n = 11), respectively. HRs of aortic and mitral valve/annulus calcium volume for cardiovascular events were 1.46 (95 % CI, 1.09–1.84) and 2.74 (95 % CI, 0.92–4.56) per 500 mm3. The c-statistic of a basic model including age, pack-years, current smoking status, coronary and aorta calcium volume was 0.68 (95 % CI, 0.63–0.72), which did not change after adding heart valve calcium volume. Aortic valve calcifications are predictors of future cardiovascular events. However, there was no added prognostic value beyond age, number of pack-years, current smoking status, coronary and aorta calcium volume for short term cardiovascular events

    Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study

    Get PDF
    To assess whether absolute mass scores are comparable or differ between identical 64-slice MDCT scanners of the same manufacturer and to compare absolute mass scores to the physical mass and between scan modes using a calcified phantom. A non-moving anthropomorphic phantom with nine calcifications of three sizes and three densities was scanned 30 times on three 64-slice MDCT scanners of manufacturer A and on three 64-slice MDCT scanners of manufacturer B in both sequential and spiral scan mode. The mean mass scores and mass score variabilities of seven calcifications were determined for all scanners; two non-detectable calcifications were omitted. It was analyzed whether identical scanners yielded similar or significantly different mass scores. Furthermore mass scores were compared to the physical mass and mass scores were compared between scan modes. The mass score calibration factor was determined for all scanners. Mass scores obtained on identical scanners were similar for almost all calcifications. Overall, mass score differences between the scanners were small ranging from 1.5 to 3.4% for the total mass scores, and most differences between scanners were observed for high density calcifications. Mass scores were significantly different from the physical mass for almost all calcifications and all scanners. In sequential mode the total physical mass (167.8 mg) was significantly overestimated (+2.3%) for 4 out of 6 scanners. In spiral mode a significant overestimation (+2.5%) was found for system B and a significant underestimation (−1.8%) for two scanners of system A. Mass scores were dependent on the scan mode, for manufacturer A scores were higher in sequential mode and for manufacturer B in spiral mode. For system A using spiral scan mode no differences were found between identical scanners, whereas a few differences were found using sequential mode. For system B the scan mode did not affect the number of different mass scores between identical scanners. Mass scores obtained in the same scan mode are comparable between identical 64-slice CT scanners and identical 64-slice CT scanners on different sites can be used in follow-up studies. Furthermore, for all systems significant differences were found between mass scores and the physical calcium mass; however, the differences were relatively small and consistent

    CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting—a consensus document by the European Society of Cardiovascular Radiology (ESCR)

    Get PDF
    Abstract: Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient’s quality of life and prolong short- and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. Key Points • To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. • To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. • To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning

    Relationship between the number of new nodules and lung cancer probability in incidence screening rounds of CT lung cancer screening: The NELSON study

    Get PDF
    Background: New nodules are regularly found after the baseline round of low-dose computed tomography (LDCT) lung cancer screening. The relationship between a participant's number of new nodules and lung cancer probability is unknown. Methods: Participants of the ongoing Dutch-Belgian Randomized Lung Cancer Screening (NELSON) Trial with (sub)solid nodules detected after baseline and registered as new by the NELSON radiologists were included. The correlation between a participant's new nodule count and the largest new nodule size was assessed using Spearman's rank correlation. To evaluate the new nodule count as predictor for new nodule lung cancer together with largest new nodule size, a multivariable logistic regression analysis was performed. Results: In total, 705 participants with 964 new nodules were included. In 48% (336/705) of participants no nodule had been found previously during baseline screening and in 22% (154/705) of participants >1 new nodule was detected (range 1–12 new nodules). Eventually, 9% (65/705) of the participants had lung cancer in a new nodule. In 100% (65/65) of participants with new nodule lung cancer, the lung cancer was the largest or only new nodule at initial detection. The new nodule lung cancer probability did not differ significantly between participants with 1 (10% [56/551], 95%CI 8–13%) or >1 new nodule (6% [9/154], 95%CI 3–11%, P =.116). An increased number of new nodules positively correlated with a participant's largest nodule size (P < 0.001, Spearman's rho 0.177). When adjusted for largest new nodule size, the new nodule count had a significant negative association with lung cancer (odds ratio 0.59, 0.37–0.95, P =.03). Conclusion: A participant's new nodule count alone only has limited association with lung cancer. However, a higher new nodule count correlates with an increased largest new nodule size, while the lung cancer probability remains equivalent, and may improve lung cancer risk prediction by size only
    corecore